a) manually and with memory function (daily repetition of an UP or DOWN command) or b) manually and with matte integration into a matte-compatible Smarthome control center
Control of several roller shutter drives with one switch
In general, only one drive may be connected per switch. If additional motors are to be operated with one switch for parallel operation, SIRAL cut-off relays must be installed!
must be installed! Except for the exclusive use of the SIRAL EL4 or EL1 motor. In addition, the maximum switching capacity of 500 watts must not be exceeded!
Setting options
Manual operation
Direct operation at the switch: The roller shutter is started by pressing the UP or DOWN button and moves to the end position set on the motor. The roller shutter switch has a
The shutter switch is self-retaining for 180 seconds in each direction (when not set up or not calibrated). A movement can be interrupted at any time by pressing the STOP button.
Memory function
(Not possible if the switch is integrated into a Matter-compatible Smarthome central control unit) An opening and closing time can be programmed for each day. These times are
identical on every day of the week.
Control via a matter-compatible app
On delivery, the switch is in set-up mode for 5 minutes after restarting (recognizable by the yellow flashing LED). While set-up mode is active, the switch can be
the switch can be integrated into your WLAN or Matter network using a Matter-enabled app from a third-party provider. The QR code or numerical code required for manual
Code can be found on the back of the switch insert or enclosed in the packaging. For further instructions on setting up, please refer to the operating instructions and the
Instructions of the third-party app you are using.
The SIRAL roller shutter switch matter implements the "Window Covering" device type in accordance with the Matter specification version 1.1. The following features and all associated mandatory
mandatory commands and attributes are supported: Lift, PositionAwareLift
The position of the blind is determined via a time measurement, which must be calibrated in order to use the PositionAwareLift feature. The calibration procedure ("Teach in travel times")
can be found in the operating instructions. In the uncalibrated state, the self-retaining travel time is 180 seconds.
The switch also supports the following optional attributes:
NumberOfActuationsLift, Mode: Reversed Movement, Maintenance Mode, LEDs off
Important!
With Apple Home and other apps, it is necessary to teach in the travel time up to the end positions so that the switch can be displayed and controlled correctly.
Please refer to the operating instructions on page 5, section 3.
- Operating mode: Wired
- Color: white
- Operating temperature: 0°C to +50°C
- Suitable for: all manufacturers
- Power supply: 230V
- Protection class: IP20
- Ambient conditions: dry living spaces
- Radio protocol: MATTER
- Product group: Siral controls
- Additional Description: A Matter-compatible WLAN shutter timer