Function module MS-Z2 / JU-Z2

  • Functionality like JU-Z1, with the difference that
    The blind travel time cannot be stopped on site

Commission:
Prices visible after login
1 In stock
: 24.12.2024 - 28.12.2024 (DE - int. shipments may differ)
Description

Function

The MS-Zxx control module can be used to upgrade any MS-Gxx motor control unit that already contains a dead man's control as a basic device to various operating functions
can be upgraded. To do this, simply remove the connection diodes from the connector strips of the basic device and attach the MS-Zxx control module.
The terminal strip on the MS-Zxx can be used to connect a maximum of 10 additional base units via the synchronous line if they are all to be operated with the same individual switching point.

Function "MS-Z1" Standard

priority function:
If a central UP command is present via the ring line, the individual switching point is blocked for this time.

Equal priority function:
The central-AB and local-AUF-AB control commands have equal priority; this means that a central-AB command
can be counteracted at any time with the individual switching point.

Key logic:
If the individual switching point is actuated briefly (jog mode), the blind only runs for a short time (e.g. turning).
If the switch-on point is pressed > 1 time, the control unit switches to self-retaining mode and the blind moves to the end position.
The blind can be stopped during the travel time by pressing a button again (UP or DOWN).

Pulse switching:
With radio or IR control via pulses, inputs 21+22 can be bridged. The control unit then switches
switches in a rolling UP-STOP-AB sequence for each pulse.

Switch-off logic:
If a central or local run command is set, the control module switches the output off again after 150 seconds.
This prevents voltage being applied to the motor for a longer period of time.

Automatic:
The central AB command can be disabled for 12 hours via an external button. The blocking is indicated by an indicator light
is displayed. If the block is to be released prematurely, the button must be pressed again (indicator light goes out).

MS-Z2" function (without intermediate stop)

Functionality as for JU-Z1, with the difference that the blind travel time cannot be stopped on site.
This ensures that all hangings can only ever be fully lowered and raised.


PDF
Datenblatt
Function module MS-Z1 / JU-Z1
Function module MS-Z1 / JU-Z1
Prices visible after login

Motor control unit JU-G1 for Veltrup
Motor control unit JU-G1 for Veltrup
Prices visible after login

suitable for connection of one motor
Motor control unit JU-G1 for Veltrup
Motor control unit JU-G1 for Veltrup
Prices visible after login

suitable for connection of one motor
Loading ...