Motor control "Dwell time logic"


Commission:
Prices visible after login
3 In stock
: 24.12.2024 - 28.12.2024 (DE - int. shipments may differ)
Description

Application

The latching time logic control unit is used in decentralized systems. The control units are installed close to the motors and switches.
Integrated in boxes, they are housed in suspended ceilings, wiring ducts or recesses provided by the customer. The control cable is looped, i.e.
from control unit to control unit and connected to it on site. The control unit is used to control motors with max. 250V~.
The control voltage is supplied via an upstream power supply unit.

Function

Operation is via a control panel and/or push-buttons. The term time logic stands for a special sequence within the control units for group and/or individual operation within groups = hierarchical operation
or individual operation within groups = hierarchical structures with push-button switches. As long as a signal is present, motors are switched via the central input according to the output voltage
in both directions according to the output voltage. Signals via the individual switch input are executed in the range of up to 2 seconds,
as long as they are present. If they last longer than 2 seconds, they are saved (self-holding) and kept active until the limit switch is reached.
To stop, press the button in the opposite direction. At the central input +24VDC is applied to the direction terminals (16,17/18,19), at the individual switch input terminal P(21)'
is switched to the direction terminals (20/22). If signals from the central unit and push-button are present at the same time, the central command has priority over the push-button command.
Priority is given to the retract command if both direction signals from the central unit or the individual switch are present at the same time.

When used as a group control unit, +24V is switched to terminal L(1,2), the conductor rail from the central control unit is connected to the central input and the group to be switched is connected to the motor output
group to be switched is connected to the motor output.


PDF
Datenblatt
Standard" motor control unit
Standard" motor control unit
Prices visible after login

suitable for connection of one motor
Motor control housing SG03
Motor control housing SG03
Prices visible after login

Motor control housing SG03
Motor control housing SG03
Prices visible after login

Loading ...