Function
Individual control is carried out by the local control switch. With central control, the local control point central command is locked and the corresponding command is executed.
If the local switch is left engaged, it remains locked after completion of the central command until it is moved to the "OFF" position.
Only then is a new local control command possible. By linking the load contacts, the "UP" command is always executed when "UP" and "DOWN" are activated simultaneously
- Operating mode: Individual or central operation
- Connection for motors: for 1 motor
- Product group: Motor control
- Suitable for: Veltrup
- Plug connection: Terminal strip
- Power supply: 24V DC
- Additional Description: suitable for connection of one motor